-
Lnc-RT Heroᵀᴹ I(With gDNase)(Super Premix for first-strand cDNA synthesis from lncRNA)
Super Premix for first-strand cDNA synthesis from lncRNA
Cat.No.RTL-09098/09099
Fast and highly sensitive reverse transcription system for generating first-strand cDNA from lncRNA.
Remove gDNA in 2 minutes.
15 minutes to complete the synthesis of the first strand cDNA
High-sensitivity reverse transcription system
High thermal stability,the optimal reaction temperature is 42℃, and it still has good reverse transcription performance at 50℃.
-
RT Easyᵀᴹ I Master Premix for first-strand cDNA synthesis
- Efficient reverse transcription system, it only takes 25 minutes to complete the synthesis of the first strand cDNA.
- High-sensitivity reverse transcription system, pg-level templates can also get high-quality cDNA.
- The reverse transcription system has high thermal stability, the reaction temperature of the system can be as high as 50 ℃, and it has good reverse transcription performance.
- Even impure RNA samples (alcohol up to 45%, guanidine salt up to 750mM) can be subjected to reverse transcription reaction.
-
RT Easy II(with gDNase) Master Premix for first-strand cDNA synthesis for Real Time PCR with gDNase
-Efficient ability to remove gDNA, which can remove gDNA in the template within 2 minutes.
-Efficient reverse transcription system, it only takes 15 minutes to complete the synthesis of the first strand cDNA.
-Complex templates: templates with high GC content and complex secondary structure can also be reversed with high efficiency.
-High-sensitivity reverse transcription system, pg-level templates can also get high-quality cDNA.
-The reverse transcription system has high thermal stability, the optimal reaction temperature is 42℃, and it still has good reverse transcription performance at 50℃.
-
RT Easyᵀᴹ II Master Premix for first-strand cDNA synthesis for Real Time PCR
- Efficient reverse transcription system, it only takes 20 minutes to complete the synthesis of the first strand cDNA.
- High-sensitivity reverse transcription system, pg-level templates can also get high-quality cDNA.
- The reverse transcription system has high thermal stability, the reaction temperature of the system can be as high as 50 ℃, and it has good reverse transcription performance.
- Even impure RNA samples (alcohol up to 60%, guanidine salt up to 750mM) can be subjected to reverse transcription reaction.
- 2× RT OR-EasyTM Mix has added optimized reverse transcription primers (Random Primer, Oligo(dT)18 Primer).